7.22.17 boSerialStatus
Result of the serial error detection mechanism. The value is reset with each read ac-
cess. Several bits can be set simultaneously.
Name boSerialStatus
Category boSerialControl
Interface IInteger
Access Read only
Unit -
Values
0x0 ... 0xFFFFFFFF (Increment: 1)
The hexadecimal value is to be interpreted as follows:
0x00000010 break detect
0x00000008 framing error
0x00000004 parity error
0x00000002 receive overrun error
7.22.18 boSerialWrite
Command to write data to serial interface.
Name boSerialWrite
Category boSerialControl
Interface ICommand
Access Write only
Unit -
Values -