EasyManua.ls Logo

Baumer VLXT - Exposuretimegapmin (≥ Release 3 Only); Readoutmode

Baumer VLXT
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
V2.6 | 8/30/2022 | 1120758
7.1.14 ExposureTimeGapMin(≥Release3only)
Returns the minimum value of the exposure time gap.
Name ExposureTimeGapMin
Category AcqusitionControl
Interface IFloat
Access Read only
Unit μs
Values 0 - 2,000,000.000000 (Increment: 1.00)
7.1.15 ReadoutMode
Species the operation mode of the readout for the acquisition.
Image acquisition consists of two separate procedures carried out in succession.
Exposing the pixels on the photosensitive surface of the sensor is only the rst part of the 
image acquisition process. Once this rst step is completed, the pixels are read out.
The exposure time (t
exposure
) can be adjusted by the user, however, the time needed for the
readout (t
readout
) is determined by the particular sensor and image format in use.
The cameras can be operated sequential or overlapped depending on the mode and the
combination of exposure and readout times used:
Sequential Overlapped
Here, the time intervals are long enough
for the exposure and readout to be pro-
cessed successively.
In this operation mode, frame (n+1) is ex-
posed whilst frame (n) is being read out.
Exposur
e
Readout
Exposur
e
Readout
Name ReadoutMode
Category AcqusitionControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Overlapped Overlapped ReadoutMode
Sequential Sequential ReadoutMode