7.1.23 TriggerSource
Species the internal signal or physical input Line to use as the trigger source. The se-
lected trigger must have its TriggerMode set to On.
Name TriggerSource
Category AcqusitionControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Action1
Species  which  Action  command  to  use  as  internal 
source for the trigger.
All All trigger sources are active.
Counter1End
(≥ Rel. 2 only)
Species which of the Counter signal to use as internal 
source for the trigger.
Counter2End
(≥ Rel. 2 only)
Species which of the Counter signal to use as internal 
source for the trigger.
Line0
Species which physical line (or pin) and associated I/O 
control block to use as external source for the trigger
signal.
Line1
Species which physical line (or pin) and associated I/O 
control block to use as external source for the trigger
signal.
Off No trigger source is active.
Software
Species  that  the  trigger  source  will  be  generated  by 
software using the TriggerSoftware command.

Table of Contents