64
V2.6 | 8/30/2022 | 1120758
7.1.23 TriggerSource
Species the internal signal or physical input Line to use as the trigger source. The se-
lected trigger must have its TriggerMode set to On.
Name TriggerSource
Category AcqusitionControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Action1
Species which Action command to use as internal
source for the trigger.
All All trigger sources are active.
Counter1End
(≥ Rel. 2 only)
Species which of the Counter signal to use as internal
source for the trigger.
Counter2End
(≥ Rel. 2 only)
Species which of the Counter signal to use as internal
source for the trigger.
Line0
Species which physical line (or pin) and associated I/O
control block to use as external source for the trigger
signal.
Line1
Species which physical line (or pin) and associated I/O
control block to use as external source for the trigger
signal.
Off No trigger source is active.
Software
Species that the trigger source will be generated by
software using the TriggerSoftware command.