172
V2.6 | 8/30/2022 | 1120758
7.17.9 FocusStatus (.EF only)
Reads the status of the Focus feature.
Name FocalLengthStatus
Category OpticControl
Interface IEnumeration
Access Read only
Unit -
Values
Busy The focus executes a feature access/command.
Error The focus encountered an error.
Not Connected The focus is physically not connected.
Not Initialized The focus is not initialized.
Not Supported The focus is physically connected but not supported.
Ready The focus is ready to use.
7.17.10 FocusStepper
FocusStepper controls the stepper value of the Focus, e.g. ObjectSensorDistance or Fo-
calPower. 0 is the closest focus.
Notice
The cameras are frequently installed in industrial environments. These environments
often include devices that generate electromagnetic interference (EMI) and they are
prone to electrostatic discharge (ESD). Excessive EMI and ESD can change the set
focus. Update this value if necessary.
Name FocusStepper
Category OpticControl
Interface IInteger
Access Read / Write
Unit -
Values
e.g. 0 ... 46000 (Increment: 1)
value range depending on lens

Table of Contents