EasyManua.ls Logo

Baumer VLXT - Page 119

Baumer VLXT
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
119
V2.6 | 8/30/2022 | 1120758
Event Event-ID Description
DeviceTemperature
StatusChanged
0x9030 Status of the internal device temperature has been
changed.
EventLost 0x9021 Event was lost in the camera.
ExposureEnd 0x9001 Exposure ended.
ExposureStart 0x9000 Exposure started.
FrameEnd 0x9003 Device just completed the capture of one Frame.
FrameStart 0x9002 Device just started the capture of one Frame.
FrameTransfer-
Skipped
0x9019 The event will be generated when the internal camera
buffer is overowed and and image has been lost.
GigEVisionError 0x9020 Device just detected an error.
GigEVisionHeartbe-
atTimeOut
0x9023 Device runs in heartbeat timeout.
Line0FallingEdge 0x9008 Falling Edge is detected on the Line 0.
Line0RisingEdge 0x9007 Rising Edge is detected on the Line 0.
Line1FallingEdge 0x900A Falling Edge is detected on the Line 1.
Line1RisingEdge 0x9009 Rising Edge is detected on the Line 1.
Line4FallingEdge 0x9010 Falling Edge is detected on the Line 4.
Line4RisingEdge 0x900F Rising Edge is detected on the Line 4.
Line5FallingEdge 0x9012 Falling Edge is detected on the Line 5.
Line5RisingEdge 0x9011 Rising Edge is detected on the Line 5.
Line6FallingEdge 0x9014 Falling Edge is detected on the Line 6.
Line6RisingEdge 0x9013 Rising Edge is detected on the Line 6.
Line7FallingEdge 0x9016 Falling Edge is detected on the Line 7.
Line7RisingEdge 0x9015 Rising Edge is detected on the Line 7.
PrimaryApplication-
Switch
0x0007 For systems where redundancy and fault recovery are
required, it is often necessary for a second application
to take control over the camera that is already under
the control of a primary application. In order to notify
the primary application that a switchover has occurred,
send this event before granting access to new primary
application.
PtpServoStatus-
Changed
(≥ Rel. 2 only)
0x9032 The event will be generated when the status of the
internal PTP servo has been changed.
PtpStatusChanged
(≥ Rel. 2 only)
0x9031 The event will be generated when the status of the
internal PTP state machine has been changed.
Notice
There is a possibility that a large number of events
PtpStatusChanged will be issued as long as PtpSer-
voStatus ≠ Locked.
TransferBufferFull 0x9017 The event will be generated when no internal camera
buffer is available.
TransferBuffer-
Ready
0x9018 The event will be generated when an internal camera
buffer is available again.
TriggerOverlapped 0x9005 Trigger Overlapped.
TriggerReady 0x9004 Camera is able to process incoming trigger.
TriggerSkipped 0x9006 Camera reject an incoming trigger signal.