3-153
Confidential
(6) Disconnect the two Connectors (CN2 and CN3) from the High-voltage power supply PCB
ASSY.
(7) Disconnect the HVPS flat cable from the Connector (CN1) of the High-voltage power
supply PCB ASSY.
Fig. 3-222
Fig. 3-223
Assembling Note:
- As the DCLN coil spring and CHG 1 coil spring tend to come out of the Side frame R, be
careful not to lose them.
-
When assembling the High-voltage power supply PCB ASSY, make sure that the CHG 1 coil
spring and CHG 2 coil spring properly come into contact with the electrodes. If not, Drum
Error will occur
.
High-voltage power supply PCB ASSY
CN2
CN3
CN1
HVPS flat cable
Connector
Connector
6
6
7
<Right side>
Side frame R
DCLN coil spring
CHG 1 coil spring
CHG 2 coil spring
<Back side><Front side>