ELECTRICAL
ELECTRIC STARTER SYSTEM
Check for continuity across magnetic switch
"S"
terminal and
"M"
terminal.
If
no
continuity, replace coil.
1. US" terminal
004771
2. "M" terminal
3. "8 " terminal
Check for continuity across magnetic switch "S"
terminal
and coil case.
If not continuity, replace coil.
004772
88
Place plunger against a flat surface and push the
magnetic switch down. With switch
held down,
check for continuity between
terminal "8" and ter-
minal"M."
If
no
continuity, replace the magnetic switch and/
or
plunger.
004773