4
Technical Specifications
26/130 ekr CON 100 – Installation and Operating Manual
4 Technical Specifications
4.1 Controller
4.1.1 Ambient Conditions
DANGER
Danger of death when operated in potentially explosive areas!
►
The system must not be installed or operated in potentially
explosive areas.
Ambient condition Permissible values
Working temperature 0 to +50°C
Storage temperature -10 to +70°C
Humidity during operation 5% to 90%, non-condensing
Place of installation Closed, dry building
4.1.2 Protection Category
Controller
Protection category IP40 (with dummy plug)
4.1.3 Power Supply
Plug X100
Voltage 24 V⎓ ± 10% (including ripple)
Current max. 4A
(with actuator EMS10, EMS18)
max. 7A
(with actuator EMS21, EMS22,
ECOEMS22)
Connection 4-pin micro-style connector M8
Length of connecting cable
(with wire cross section 0.5mm
2
)
max. 20m
(with actuator EMS10, EMS18)
max. 5m
(with actuator EMS21, EMS22,
ECOEMS22)