Installation
6
ekr CON 100 – Installation and Operating Manual 39/130
►
Do not climb onto or walk on BST components or unsuitable
parts of the machine.
►
Ensure that there is sufficient free headroom. If the free head-
room is restricted, the relevant components causing the height
restrictions must be padded and danger-warning signs must be
attached to them (yellow / black).
After completing the installation work
►
Install all safety equipment and protective covers that had to
be removed for the installation work.
►
Check that the bolts are screwed tight.
►
Remove all tools and auxiliary aids used from the machine.
►
Before commissioning, remove any transport locks present
from the BST components.
6.2 Selecting the Installation Location
DANGER
Danger of death when operated in potentially explosive areas!
►
The system must not be installed or operated in potentially
explosive areas.
In addition to the basic ambient conditions (see Ambient Condi-
tions, page 26), the following conditions also have to be fulfilled:
■ Installation location dry, vibration-free and level
■ Ergonomic positioning
■ No direct light irradiation onto the display
■ Minimum clearance of 100 mm to electro-magnetic fields
(energy sources or high voltage lines)
■ No sources of heat in the immediate vicinity