ID-DCU-MARINE-2.2.2, ©ComAp – June 2015 - 118 -
ID-DCU-MARINE-2.2.2.pdf
Date and time
Time [ HHMMSS ]
Controller internal Real Time Clock adjustment.
Date [ DDMMYY ]
Actual date adjustment
Time Stamp Per [ min ]
Time interval for history record. Time base is based on number of minutes since midnight.
Step: 1 min
Range: 0 - 240 min
Hint:
No history Time stamp is recorded when TimeStamp Per = 0.
RTC and Date is in each History record.
SummerTimeMod [ DISABLED, WINTER, SUMMER,
WINTER-S, SUMMER-S]
The setpoint is used to select the mode of automatic daylight saving time change.
The automatic change to daylight saving time and back is disabled.
The automatic change is enabled, the current season is winter and the
controller is located in the northern hemisphere.
The automatic change is enabled, the current season is summer and the
controller is located in the northern hemisphere.
The automatic change is enabled, the current season is winter and the
controller is located in the southern hemisphere.
The automatic change is enabled, the current season is summer and the
controller is located in the southern hemisphere.
EnTimeSync [ DISABLED, ENABLED ]
The setpoint is used to enable Time synchronization function with InteliGen-NT and InteliSys-NT
controllers over CAN2 bus.
The synchronization is just unidirectional from InteliGen-NT or InteliSys-NT controller into InteliDrive-
DCU Marine, not vice versa.