EasyManua.ls Logo

ComAp InteliDrive DCU Marine - I-Aout8; I-Rbxx; I-Lb; Ig-Ib

ComAp InteliDrive DCU Marine
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ID-DCU-MARINE-2.2.2, ©ComAp June 2015 - 167 -
ID-DCU-MARINE-2.2.2.pdf
I-AOUT8
Nominal power supply 24 VDC
Power supply range 8 36 VDC
Consumption 0,1A 0,5A depends on supply voltage and load
Mechanical dimensions: 40 x 95 x 45 mm, 35 mm DIN rail mounted
Interface to controller CAN
Operating temperature -30..+70
o
C
Number of analog outputs 8 (not electrically separated)
Output range 0 to 10 VDC
0 to 20 mA (max 500 )
I-RBxx
Number relays: 16 or 8 in sockets
Nominal voltage: 24 VDC
Voltage range: 16,8 36 VDC
Relay opens at: 10% of nominal voltage
Electric / mechanic cycles: 100 000 / 10 000 000
Operating temperature range: - 40°C to 70°C
Maximal load: 6 A resistive load at 24VDC
4 A inductive load at 24 VDC
Contacts protection: varistor 14DK390
I-LB+
Power supply range 8 36 VDC
Consumption 100mA at 24 V
Mechanical dimensions: 95 x 96 x 43 mm (3.7’x3.8’x1.7’)
35 mm DIN rail mounted
Interface to controller CAN
Interface to modem or PC RS232, RS422, RS485, USB
Operating temperature -30..+70
o
C
Storage temperature -40..+80
o
C
Front panel protection IP 20
IG-IB
Nominal power supply 24 VDC
Power supply range 8 36 VDC
Consumption 100 300mA
Mechanical dimensions 150 x 160 x 50 mm
35 mm DIN rail mounted
Interface RS232 to controller
RS232 to Modem
CAN bus
Ethernet
Operating temperature -30..+70
o
C
Storage temperature -30..+70
o
C
Front panel protection IP 20