ID-DCU-MARINE-2.2.2, ©ComAp – June 2015 - 98 -
ID-DCU-MARINE-2.2.2.pdf
Source: Statistics
NumSuccStarts
Successful engine start number counter. The counter is increased by 1 even if the particular start command
will take more than one attempt.
Hint:
The counter can be readjusted/reset from InteliMonitor menu Monitor -> Set statistics.
NumUnscStarts
Unsuccessful starts counter. The counter is incremented always when Start fail alarm is issued.
Hint:
The counter can be readjusted/reset from InteliMonitor menu Monitor -> Set statistics.
Service Time
This is maintenance countdown timer. The timer is located in setpoints group Engine protect as well as in
Statistics values. Adjust the timer to the requested maintenance interval. It will be decremented while the
engine is running. The alarm WrnServiceTime is issued as soon as the timer counts down to zero.
Memo1, Memo2
There are two Statistics registers Memo1 and Memo2. Those statistic values are based on Logical Analog
Input Memory1 or Memory2 value in the time of Logical Binary input Memo1 Trigger or Memo2 Trigger
rising edge. Both statistics values is possible to modify in InteliMonitor – Set Statistics command.