RAPID CONFIGURATION
4
MATRIX 320
3. Release the button to enter the Aim function. The laser pointer turns on, and the
Autofocus procedure begins. The Aim LED will blink until the procedure is com-
pleted.
4. Place the Grade A Barcode Test Chart in front of the reader at the correct reading
distance for your application (see the
Global FOV Diagrams, starting on page 111 for
reference). The center of the cross is 16 mm (14 LEDs model) or 30 mm (36 LEDs
model) under the optical axis, as shown in Figure 8.
Within 3 seconds (before the reader flashes), center one of the larger codes on
the aiming system pointer (the code must not move during this procedure).
The Autofocus procedure ends when the Reading Distance and PPI values are suc-
cessfully saved in the reader memory, the Aim LED will stop blinking and Matrix
320 emits 3 high pitched beeps.
If the Autofocus cannot be reached after a timeout of about 3 (three) minutes,
Matrix 320 will exit without saving the parameters to memory, the Aim LED will
stop blinking and in this case Matrix 320 emits a long low pitched beep.
Figure 7 - X-PRESS Interface; Aim/Autofocus Function
Figure 8 - Cross Laser Pattern
Now skip to Next Steps for All Models, starting on page 6.
NOTE
You can exit the Aim/Autofocus function at any time by pressing the
X-PRESS push button once. After a short delay the Autofocus procedure
is canceled and the laser pointer turns off.