EasyManua.ls Logo

Datalogic Matrix 320 - Page 71

Datalogic Matrix 320
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPLICATION EXAMPLES
PRODUCT REFERENCE GUIDE
53
To improve decodability when the FoV includes codes with different levels of con-
trast:
In the example above, when HDR is disabled only two out of four codes are decoded.
After enabling HDR, all four codes are decoded.
In high speed applications, because Exposition Time can be reduced when HDR is
enabled. The allowed Exposition Time (T
exp
) must be less than the code resolution
(X) divided by the line speed (LS):
T
exp
< (X/ LS)
In the example above, C128 13 mils (0.33 mm) codes at a distance of 200 mm must be
decoded. When HDR is disabled, good image contrast is obtained with the Exposition
HDR disabled HDR enabled
HDR
disabled
HDR
enabled