Make sure machine head (or arms) closes properly. (On machines with Single Stage initiation,
depressing the foot switch will sequence the control but will not weld.)
Machine will sequence but will not weld, then the
head (or arms) will retract.
Put the control in WELD mode (see Figure B-18).
Place sample parts to be welded between
electrodes, and initiate weld sequence again.
Machine head (or arms) will close on parts to be
welded. (On machines with Single Stage initiation,
depressing the foot switch will sequence the
machine and weld.)
Machine will go through sequence, and weld, then
the head (or arms) will retract.
Figure B-19. Welding
the sample part
Figure B-17.
Closed head or
arms
Figure B-18. Put control in WELD mode