Operating manual
CNC 8070
SETUP ASSISTANCE
20.
(REF: 1505)
·355·
Oscilloscope
The oscilloscope can represent up to two variables of each device that may be DRV variables
or the device's own variables (MLINK0 to MLINKF). These variables will be associated with
the devices through their name (MLINK7.X) or through the node number (MLINK7.1).
The oscilloscope can access the parameters of the device using its identifier (hexadecimal
number between P0000 and PFFFF).
Saving, loading and resetting the condigurations
When defining a new configuration of variables to be displayed and parameters modified at
the oscilloscope, the system allows saving that configuration into a file. Likewise, the system
allows loading a configuration that was saved previously or resetting the current
configuration.
Save
To save the current configuration, go to the configuration screen and press the "Save" softkey.
After this, a new screen appears showing the available configurations with the focus on the
last one. Also, it is possible to rename the new configuration whose extension must be "osc".
Load
To load a previously saved configuration, go to the configuration screen and press the "Load"
softkey. Then, a new screen appears showing a list of previously saved configurations, being
possible to select any of them.
Reset
Pressing the "Reset" softkey of the configuration screen deletes or initializes the current
configuration. There are neither variables nor parameters selected and the rest of conditions
(colors, trigger, etc.) assume the values assigned by default.