·376·
Operating manual
CNC 8070
20.
SETUP ASSISTANCE
(REF: 1505)
The circularity (roundness) test
20.3.8 Validate the changes and save the configuration used
Validate the parameters
The new data is assumed by the CNC until the unit is turned off. Once the setup is completed,
the changes must be saved so they can be effective next time the CNC is turned on.
Save and load the configuration
The system permits saving the current configuration into a file in ASCII format (extension
"TST"). This file only contains the configuration. It contains neither the graphics nor the
values of the machine parameters. When loading a configuration, the parameters assume
the value they have at the time.
Save the configuration
Press the "Save" softkey to save the current configuration. Select the folder and the file name
and press [ENTER]. If there is a configuration already saved with the same name, it will ask
whether it is to be replaced or not.
By default, the configuration is saved in the folder "C:\CNC8070 \MTB \DATA" or in the last
folder selected by the user.
Load the configuration
Press the "Load" softkey to load a previously saved configuration. Select the folder and the
file name and press [ENTER].
Use the "Validate" softkey to save the data. The CNC saves the new values in the CNC tables
and/or in the drive tables accordingly.
When quitting the circularity test without having saved the parameters, the CNC will show
a message warning about it and will give a chance to save them.
The configuration saving option does not update the machine parameter table. To do that, use the
Validate softkey.