Troubleshooting
6-27
Exception
ID
Error
Warning
Exception
Description
(In system Log)
Message
(Displayed in User Interface)
Diagnosis Reference
0304511
Warning
Set current
exam to
Imaging Engine
failed
Set current exam failure.
Please restart the system. If
this issue persists, please call
for service.
1. Restart the system.
2. If not work, re-install
Workstation software.
3. If not work, re-install OS.
0304512
Warning
Delete image
by exam tco
failed
Delete exam exception. Please
try again. If this issue persists,
please call for service.
1. Restart the system.
2. If not work, re-install
Workstation software.
3. If not work, re-install OS.
0304513
Warning
Get text
resource failed
Get text resource failure.
Application display may be
abnormal. Please restart the
system. If this issue persists,
please call for service.
1. Restart the system.
2. If not work, re-install
Workstation software.
3. If not work, re-install OS.
0304514
Warning
Load
connectivity
configuration
file fail
Connectivity configuration
loading failure. Some
configuration may be missed.
Please restart the system. If
this issue persists, please call
for service.
1. Restart the system.
2. If not work, re-install
Workstation software.
3. If not work, re-install OS.
0304516
Warning
Load default
storage server
failed
Connectivity configuration file
loading exception. Default
storage server setting is
missed. Please restart the
system. If this issue persists,
please call for service.
1. Restart the system.
2. If not work, re-install
Workstation software.
3. If not work, re-install OS.
0304517
Warning
Init exam list
option failed
Setup configuration loading
failure. Exam list display setting
missed. Please restart the
system. If this issue persists,
please call for service.
0304518
Warning
Init height &
weight unit
failed
Setup configuration loading
failure. Weight/Height units
missed. Please restart the
system. If this issue persists,
please call for service.
1. Restart the system.
2. If not work, re-install
Workstation software.
3. If not work, re-install OS.
0304519
Warning
Init default
MPPS server
failed
Connectivity configuration
loading failure. Default MPPS
server setting missed. Please
restart the system. If this issue
persists, please call for service.
1. Restart the system.
2. If not work, re-install
Workstation software.
3. If not work, re-install OS.