MDS 05-6632A01, Rev. F MDS Orbit MCR/ECR Technical Manual 115
Figure 3-60. ISM 900 (NX) Connection Status
CLI Configuration Examples
AP Mode
On the next page, the example will display how to configure the NX915 module as an access point with
the network name of ‘MyNetwork’ and default settings.
% set interfaces interface NxRadio nx-config device-mode access-point network-name
MyNetwork
% show interfaces interface NxRadio nx-config | details
modem-mode 500kbps;
device-mode access-point;
network-name MyNetwork;
data-compression none;
header compression false;
power 30;
dwell-time 50;
beacon-interval 150;
hop-set a;
security {
security-mode none;
encryption none;
}