MDS 05-6632A01, Rev. F MDS Orbit MCR/ECR Technical Manual 383
Table 4-6. LnRadio Interface LED Descriptions
LED - NIC2
State
Description
LnRadio Interface
Off
Interface disabled
Access Point Mode
Blink Red
Solid Red
Solid Green
LN NIC Initialization
No Remotes connected
Linked with at least 1 Remote
Remote Mode
Blink Red
Solid Green
LN NIC Initialization / Not linked to an Access
Point
Linked with Access Point
NOTE In addition to the LEDs listed on the previous page, the Ethernet connector has two embedded
LEDs. A yellow indicates a link at 100 Mbps operation. A flashing green indicates Ethernet
data traffic.
4.2 Technical Specifications
GENERAL
Input Power
11 to 55 VDC, NOMINAL
10 to 60 VDC, 15 Watts maximum (depending on configuration)
Below are power consumption figures for common configurations:
Typical High Throughput Wi-Fi power consumption <= 4.1 Watts
Minimum Wi-Fi power consumption <= 3.4 Watts
Table 4-7. Orbit MCR-4G Power Consumption:
Power Consumption (nominal, 25C, Cellular Only)
Mode
Power
13.8V
Connected (Idle)
4.0W
292mA
Connected (Typical Download)
4.3W
310mA
Table 4-8. Orbit MCR-3G Power Consumption:
Power Consumption (nominal, 25C, Cellular Only)
Mode
Power
13.8V
Connected (Idle)
2.5W
182mA
Connected (Typical Download)
3.2W
235mA