MDS 05-6632A01, Rev. F MDS Orbit MCR/ECR Technical Manual 27
NOTE GE MDS part number 73-2434A25 provides a custom RJ45 to DB9 Adapter for use with the
Orbit MCR and other GE MDS products. The chart below provides details for connections
made using this adapter.
WIRING CHART
RJ-45 PIN
FUNCTION
DB9 PIN
1
DSR
6
2
DCD
1
3
DTR
4
4
GND
5
5
RXD
2
6
TXD
3
7
CTS
8
8
RTS
7
LED Status IndicatorsThe LEDs on the unit provide visual indications of the status of the device as
shown in the following chart:
Figure 2-6. LED Status Indicators
Table 2-4. Description of LED Status Indicators
LED Name
LED State
Description
PWR
(DC Power)
Off
Solid Green
Fast Blink/Red (1x/sec.)
No power to unit
Unit is powered, no problems detected
Alarm indication
ETH
(Ethernet)
Off
Solid Green
Blinking Green
No Ethernet link to network
Ethernet link present
Ethernet traffic in/out
COM
(Serial Comm. Port)
Off
Blinking Green
No serial connection, or idle
Serial traffic in/out
NIC1
Off
Solid Green
Interface disabled
Interface enabled
NIC2
Off
Solid Green
Interface disabled
Interface enabled
NOTE In addition to the LEDs above, the Ethernet connector has two embedded LEDs. A yellow
indicates a link at 100 Mbps operation. A flashing green indicates Ethernet data traffic.