9.4 Message Reference
172
Queries the measured resistance value for insulation-resistance tests
Syntax
(Query)
:MEASure:INSulation:RESistance?
Queries the measured resistance value (unit: MΩ) for insulation-resis-
tance tests.
(Response)
<Insulation-resistance test measured resistance value (NR1/NR2)>
9999................................O.F.
0.0...................................U.F.
0......................................No value
(Query)
:MEASure:INSulation:RESistance?
(Response)
100.0
The measured resistance value is 100 MΩ.
Error
The execution of this command in a state other than the TEST state causes an
execution error.
Queries the test time elapsed for insulation-resistance tests
Syntax
(Query)
:MEASure:INSulation:TIMer?
Queries the test time elapsed (unit: s) for insulation-resistance tests.
(Response)
<Insulation-resistance test time elapsed >,<Types of timers>
Insulation-resistance test time elapsed (NR2, unit: s)
Types of timers.....................0/ 1 (NR1)
0 : Test time
1 : Delay time
Example
(Query)
:MEASure:INSulation:TIMer?
(Response)
10.0,0
Test time elapsed: 10.0 s
Types of timers : Test time
Error
The execution of this command in a state other than the TEST state causes an
execution error.