135
GE1/0/48 Disabled Low 0.0 Off 0 Disabled
--- On State Ports: 0; Used: 0.0(W); Remaining: 180.0(W) ---
Table 25 Command output
Field Description
Interface Interface name of a PI.
PoE
PoE status:
• Enabled.
• Disabled.
Priority
Power priority of a PI:
• Critical (highest).
• High.
• Low.
CurPower Current power of a PI.
Oper
Operating status of a PI:
• Off—PoE is disabled.
• On—Power is being supplied to the PI correctly.
• Power-lack—Remaining guaranteed power is insufficient for a
critical PI.
• Power-deny—The PSE refuses to supply power. The power
required by the PD is higher than the configured power.
• Power-itself—The PD is using another power supply.
• Power-limit—The PSE is supplying power to the PD based on
the configured power though the PD requires more power than
the configured power.
IEEE Class
PD power class: 0, 1, 2, 3, or 4.
If the PSE does not support PD classification, this field displays a
hyphen (-).
Detection Status
Power detection status of a PI:
• Disabled—PoE function is disabled.
• Searching—The PI is searching for the PD.
• Delivering Power—The PI is supplying power for the PD.
• Fault—A fault occurred during the test.
• Test—The PI is undergoing a test.
• Other fault—A fault has caused the PSE to enter the idle status.
• PD disconnected—The PD is disconnected.
On State Ports Number of PIs that are supplying power.
Used Power consumed by the current PI.
Remaining Total remaining power of the system.
display poe interface power
Use display poe interface power to display power information for PIs.
Syntax
display poe interface power [ interface-type interface-number ]