150
Usage guidelines
You can upgrade the PSE firmware in service in either of the following modes:
• Refresh mode—Updates the PSE firmware without deleting it. You can use the refresh mode
in most cases.
• Full mode—Deletes the current PSE firmware and reloads a new one. Use the full mode if the
PSE firmware is damaged and you cannot execute any PoE commands.
Examples
# Upgrade the firmware of PSE 4 in service.
<Sysname> system-view
[Sysname] poe update refresh POE-168.bin pse 4
poe utilization-threshold
Use poe utilization-threshold to configure a power alarm threshold for the PSE.
Use undo poe utilization-threshold to restore the default power alarm threshold of the PSE.
Syntax
poe utilization-threshold value pse pse-id
undo poe utilization-threshold pse pse-id
Default
The power alarm threshold for the PSE is 80%.
Views
System view
Predefined user roles
network-admin
Parameters
value: Specifies alarm threshold as a percentage of 1 to 99.
pse pse-id: Specifies a PSE by its ID.
Usage guidelines
If PSE power usage crosses the threshold multiple times in succession, the system sends
notification messages only for the first crossing. For more information, see "Configuring SNMP."
Examples
# Set the power alarm threshold of PSE 4 to 90%.
<Sysname> system-view
[Sysname] poe utilization-threshold 90 pse 4
poe-profile
Use poe-profile to create a PoE profile and enter its view, or enter the view of an existing PoE
profile.
Use undo poe-profile to delete a PoE profile.
Syntax
poe-profile profile-name [ index ]
undo poe-profile { index index | name profile-name }