253
occurs times period period: Executes the policy if the number of log matches over an interval
exceeds the limit. The times argument specifies the maximum number of log matches in the range of
1 to 32. The period argument specifies an interval in the range of 1 to 4294967295 seconds.
Usage guidelines
Use Syslog event monitor policies to monitor log messages.
EAA executes a Syslog event monitor policy when the number of matching logs over an interval
reaches the limit.
NOTE:
EAA does not count log messages generated by the RTM module when it counts log matches.
You can configure only one event for a monitor policy. If the monitor policy already contains an event,
the new event replaces the old event.
Examples
# Configure a CLI-defined policy to monitor Syslog messages for level 3 to level 0 messages that
contain the down string. Enable the policy to execute when five log matches are found within 6
seconds.
<Sysname> system-view
[Sysname] rtm cli-policy test
[Sysname-rtm-test] event syslog priority 3 msg down occurs 5 period 6
event track
Use event track to configure a track event for a CLI-defined monitor policy.
Use undo event to delete the event in a CLI-defined monitor policy.
Syntax
event track track-list state { negative | positive } [ suppress-time suppress-time ]
undo event
Default
A CLI-defined policy does not contain a track event.
Views
CLI-defined policy view
Predefined user roles
network-admin
Parameters
track-list: Specifies a space-separated list of up to 16 track items. Each item specifies a track entry
number or a range of track entry numbers in the form of track-entry-number to track-entry-number.
The value range for the track-entry-number argument is 1 to 1024.
state { negative | positive }: Monitors state change of the track entries.
• negative: Triggers the policy when the states of the track entries change from Positive to
Negative.
• positive: Triggers the policy when the states of the track entries change from Negative to
Positive.
suppress-time suppress-time: Sets a suppress time in the range of 1 to 4294967295, in seconds.
The default value is 0.

Table of Contents

Other manuals for HPE FlexNetwork 5130 HI SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5130 HI SERIES and is the answer not in the manual?

HPE FlexNetwork 5130 HI SERIES Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork 5130 HI SERIES
CategorySwitch
LanguageEnglish

Related product manuals