323
Examples
# Enable counter sampling and set the counter sampling interval to 120 seconds on GigabitEthernet
1/0/1.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] sflow counter interval 120
sflow flow collector
Use sflow flow collector to specify an sFlow collector for flow sampling.
Use undo sflow flow collector to restore the default.
Syntax
sflow flow collector collector-id
undo sflow flow collector
Default
No sFlow collector is specified for flow sampling.
Views
Layer 2 Ethernet interface view
Predefined user roles
network-admin
Parameters
collector-id: Specifies an sFlow collector by its ID. The value range for this argument is 1 to 10.
Examples
# Specify sFlow collector 2 on GigabitEthernet 1/0/1 for flow sampling.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] sflow flow collector 2
sflow flow max-header
Use sflow flow max-header to set the maximum number of bytes (starting from the packet header)
that flow sampling can copy per packet.
Use undo sflow flow max-header to restore the default.
Syntax
sflow flow max-header length
undo sflow flow max-header
Default
Flow sampling can copy up to 128 bytes of a packet.
Views
Layer 2 Ethernet interface view
Predefined user roles
network-admin