Usage guidelines
After you configure the event, the monitor policy is triggered when the member device joins or leaves
the IRF fabric, or when a subcard is inserted in or removed from the specified subcard slot. If you do
not specify the insert or remove keyword, EAA monitors the member device for joining or leaving
the IRF fabric and the subcard slot for subcard hot-swapping.
You can configure only one event entry for a monitor policy. If the monitor policy already contains an
event entry, the new event entry replaces the old event entry.
Examples
# Configure a CLI-defined policy to monitor the member device for joining or leaving the IRF fabric.
<Sysname> system-view
[Sysname] rtm cli-policy test
[Sysname-rtm-test] event hotplug slot 1
event interface
Use event interface to configure an interface event for a CLI-defined monitor policy.
Use undo event to delete the event in a CLI-defined monitor policy.
Syntax
event interface interface-type interface-number monitor-obj monitor-obj start-op start-op start-val
start-val restart-op restart-op restart-val restart-val [ interval interval ]
undo event
Default
No interface event is configured.
Views
CLI-defined policy view
Predefined user roles
network-admin
Parameters
interface-type interface-number: Specifies an interface by its type and number.
monitor-obj monitor-obj: Specifies the traffic statistic to be monitored on the interface. For keywords
available for the monitor-obj argument, see Table 58.
start-o
p start-op: Specifies the operator for comparing the monitored traffic statistic with the start
threshold. The start threshold is crossed if the comparison result meets the condition. For keywords
available for the start-op argument, see Table 59.
start-v
al start-val: Specifies the start threshold to be compared with the monitored traffic statistic.
The value range is 0 to 4294967295.
restart-op restart-op: Specifies the operator for comparing the monitored traffic statistic with the
restart threshold. The restart threshold is crossed if the comparison result meets the condition. For
keywords available for the restart-op argument, see Table 59.
restart-va
l restart-val: Specifies the restart threshold to be compared with the monitored traffic
statistic. The value range is 0 to 4294967295.
interval interval: Specifies the interval to sample the monitored traffic statistic for a comparison. The
value range is 1 to 4294967295, in seconds. The default value is 300.

Table of Contents

Other manuals for HPE FlexNetwork 5130 HI SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5130 HI SERIES and is the answer not in the manual?

HPE FlexNetwork 5130 HI SERIES Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork 5130 HI SERIES
CategorySwitch
LanguageEnglish

Related product manuals