71
reaction trigger probe-fail
Use reaction trigger probe-fail to set the number of consecutive probe failures to determine an
operation failure.
Use undo reaction trigger probe-fail to restore the default.
Syntax
reaction trigger probe-fail count
undo reaction trigger probe-fail
Default
The NQA client notifies the feature of the operation failure when the number of consecutive probe
failures reaches 3.
Views
Any NQA template view
Predefined user roles
network-admin
Parameters
count: Specifies the number of consecutive probe failures, in the range of 1 to 15.
Usage guidelines
If the number of consecutive probe failures is reached, the NQA client notifies the feature that uses
the NQA template of the operation failure.
If you execute this command and the reaction trigger per-probe command multiple times, the most
recent configuration takes effect.
Examples
# In HTTP template view, configure the NQA client to notify the feature of the operation failure when
the number of consecutive probe failures reaches 5.
<Sysname> system-view
[Sysname] nqa template http httptplt
[Sysname-nqatplt-http-httptplt] reaction trigger probe-fail 5
Related commands
reaction trigger per-probe
reaction trigger probe-pass
reaction trigger probe-pass
Use reaction trigger probe-pass to set the number of consecutive successful probes to determine
a successful operation event.
Use undo reaction trigger probe-pass to restore the default.
Syntax
reaction trigger probe-pass count
undo reaction trigger probe-pass
Default
The NQA client notifies the feature of the successful operation event if the number of consecutive
successful probes reaches 3.