35
201510160206
Symptom: The dual-stack PPPoE server that mainly provides IPv6 services has available IPv6
addresses in the DHCPv6 address pool. PPPoE users who have no IPv4 addresses assigned
cannot log in.
Condition: None.
201509220301
Symptom: The Cellular process reboots unexpectedly.
Condition: This symptom occurs if the profile main command is executed on a cellular
interface on the MSR4000.
201510230327
Symptom: If a PPPoE user logs in and then logs out, the CIR specified in the user profile for the
user does not take effect.
Condition: This symptom occurs if the following conditions exist:
Two routers form an IRF fabric.
The PPPoE user logs in through an IRF port.
The master device reboots.
201508100249
Symptom: No information is displayed after the display voice sip call command is executed
on the MSR4000.
Condition: None.
201512180019
Symptom: The AC of an MPLS L2VPN cannot receive packets from a CE.
Condition: This symptom occurs if a Layer 3 aggregate subinterface is used as the AC of the
MPLS L2VPN.
201511250428
Symptom: Settings of the answer-time, idle-time, and trade-time parameters cannot be
deployed to interface cards related to POS terminal access.
Condition: This symptom occurs if you set the answer-time, idle-time, and trade-time
parameters in system view.
201512010169
Symptom: An error occurs on an IRF physical interface after the router reboots and some
operations are performed on the router.
Condition: This symptom occurs if two GigabitEthernet interfaces are used as IRF physical
interfaces and one of the IRF physical interfaces goes down.
201512030468
Symptom: Packet filtering does not take effect on an Ethernet interface operating in bridge
mode.
Condition: This symptom occurs if packet filtering is enabled on the Ethernet interface operating
in bridge mode.
201511210055
Symptom: Interfaces on the HMIM-8GSW or HMIM-24GSW interface card receive a large
number of ARP requests. Then, a packet statistics error occurs and the switching modules
cannot operate correctly.