6–18
6400 Line Matrix Printers Setup Guide, Cabinet and Pedestal Models
Fault
Message SolutionExplanation
Operator
Correct-
able?
062 EXHAUST FAN FAULT
Yes Sensors
cannot detect
current in fan circuit.
Power off the printer and remove
paper guide assembly (for
instructions, refer to your 6400
Maintenance Information
Manual)
. Check that the fan
cable is connected. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on the
printer
. If this message reoccurs,
contact your IBM service
representative.
NOTE:
This message should not
appear on a Pedestal
model. If this message
does appear
, contact
your IBM Service
Representative.
065 HAMMER BANK FAN FAULT
Yes Sensors
cannot detect
current in fan circuit.
Power off the printer and remove
paper guide assembly (for
instructions, refer to your 6400
Maintenance Information
Manual)
. Check that the fan
cable is connected. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on the
printer
. If this message reoccurs,
contact your IBM service
representative.
069 DATA CLEARED
N/A Appears
when data is
cleared out of printer after
Cancel
key has been
pressed.
No action necessary
.
080 POWER SUPPLY HOT
No Circuits are overheating on
the power supply board.
Contact your IBM service
representative.
082 POWER SUPPLY 8.5V FAILED
No Internal power failure.
Contact your IBM service
representative.