SECTION 5 - JLG CONTROL SYSTEM
3121642 – JLG Lift – 5-5
NOTE: Refer to Table 5-3, Machine Configuration Programming
Information and Table 5-5, Machine Model Adjustment for
default settings.
Password 33271 will give you access to level 1, which will
permit you to change all machine personalities and/or
machine setup settings.
CHANGING THESE SETTINGS MAY ADVERSELY AFFECT THE PERFORMANCE OF
YOUR MACHINE.
The flash code is indicated on the face of the platform control
box as shown:
NOTE: Flash codes are also displayed on the handheld analyzer.
For descriptions see Table 5-1, Fault Code Listing.
IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELECTRICAL/ELEC-
TRONIC COMPONENTS. SHOULD PRESSURE-WASHING BE UTILIZED TO WASH
AREAS CONTAINING ELECTRICAL/ELECTRONIC COMPONENTS, JLG INDUS-
TRIES, INC. RECOMMENDS A MAXIMUM PRESSURE OF 750 PSI (52 BAR) AT A
MINIMUM DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM THESE COMPO-
NENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS ARE SPRAYED, SPRAYING
MUST NOT BE DIRECT AND BE FOR BRIEF TIME PERIODS TO AVOID HEAVY SAT-
URATION.