12 Disturbance Analyzer Measurement
The Disturbance Analyzer measurement is used for automatic
assessment of amplitude, rate and duration of disturbances and is
commonly used for household appliances in electromagnetic
compatibility test. The Disturbance Analyzer measurement has Peak
and Quasi Peak detector traces. The traces measured values are
gapless with 500 µs resolution time. The maximum duration of
recorded traces data is 2 hours. CISPR 16–1–1 charter 9 and CISPR
14–1 define the standards of the test methods of the measurement
and the process of test result interpretation. However, the Click
measurement and analysis are not clearly described in CISPR
standard. The Disturbance Analyzer measurement is designed
based on an interpretation of the CISPR standards.
This topic contains the followig sections:
Measurement Commands for Disturbance Analyzer
"Remote Command Results for Disturbance Analyzer" on page 1029
Keysight X-Series Signal Analyzer
EMI Receiver Mode Reference
1027

Table of Contents

Other manuals for Keysight EXA N9010A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight EXA N9010A and is the answer not in the manual?

Keysight EXA N9010A Specifications

General IconGeneral
BrandKeysight
ModelEXA N9010A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals