EasyManuals Logo

Keysight EXA N9010A User Manual

Keysight EXA N9010A
1138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
3 Programming the Analyzer
List of SCPI Commands
[:SENSe]:CORRection:SA[:RF]:GAIN?
[:SENSe]:DANalyzer:CLICk:CORRection <rel_amptd>
[:SENSe]:DANalyzer:CLICk:CORRection?
[:SENSe]:DANalyzer:CLICk:COUNt <integer>
[:SENSe]:DANalyzer:CLICk:COUNt?
[:SENSe]:DANalyzer:CLICk:COUNt:STATe ON | OFF | 1 | 0
[:SENSe]:DANalyzer:CLICk:COUNt:STATe?
[:SENSe]:DANalyzer:CRATe?
[:SENSe]:DANalyzer:CRATe:<integer>
[:SENSe]:DANalyzer:CRATe:TYPe MEASured | USER
[:SENSe]:DANalyzer:CRATe:TYPe?
[:SENSe]:DANalyzer:FREQuency F150KHZ | F500KHZ | F1400KHZ | F30MHZ |
MANual
[:SENSe]:DANalyzer:FREQuency?
[:SENSe]:DANalyzer:FREQuency:MANual <freq>
[:SENSe]:DANalyzer:FREQuency:MANual?
[:SENSe]:DANalyzer:POWer[:RF]:ATTenuation <rel_amptd>
[:SENSe]:DANalyzer:POWer[:RF]:ATTenuation?
[:SENSe]:DANalyzer:POWer[:RF]:ATTenuation:AUTO OFF | ON | 0 | 1
[:SENSe]:DANalyzer:POWer[:RF]:ATTenuation:AUTO?
[:SENSe]:DEMod
[:SENSe]:DEMod?
[:SENSe]:DETector[1]|2|3[:FUNCtion] APEak | NEGative | POSitive | SAMPle |
RMS | AVERage | QPEak | CAVerage | CRMS
[:SENSe]:DETector[1]|2|3[:FUNCtion] ?
[:SENSe]:EMC:STANdard:PRESet NONE | CISPr | MIL
[:SENSe]:EMC:STANdard:PRESet?
[:SENSe]:EMC:STANdard[:SELect] NONE | CISPr | MIL
[:SENSe]:EMC:STANdard[:SELect]?
[:SENSe]:FEED IQ | IONLy | QONLy
[:SENSe]:FEED RF | AIQ | EMIXer
[:SENSe]:FEED AREFerence
[:SENSe]:FEED?
[:SENSe]:FEED?
[:SENSe]:FEED:AREFerence REF50 | REF4800 | OFF
[:SENSe]:FEED:AREFerence?
[:SENSe]:FEED:IQ:TYPE IQ | IONLy | QONLy
[:SENSe]:FEED:IQ:TYPE?
[:SENSe]:FEED:RF:PORT[:INPut] RFIN | RFIN2 | RFIO1 | RFIO2 | RFIO3 | RFIO4
[:SENSe]:FEED:RF:PORT[:INPut]?
[:SENSe]:FREQuency:CENTer <frequency>
[:SENSe]:FREQuency:CENTer ?
[:SENSe]:FREQuency:CENTer:STEP:AUTO OFF | ON | 0 | 1
[:SENSe]:FREQuency:CENTer:STEP:AUTO?
[:SENSe]:FREQuency:CENTer:STEP[:INCRement] <freq>
[:SENSe]:FREQuency:CENTer:STEP[:INCRement]?
[:SENSe]:FREQuency:MIDSpan <freq>
[:SENSe]:FREQuency:MIDSpan?
[:SENSe]:FREQuency:MODE CW | FIXed | SWEep | SCAN | TDOMain
[:SENSe]:FREQuency:MODE?
[:SENSe]:FREQuency:SPAN <frequency>
[:SENSe]:FREQuency:SPAN?
[:SENSe]:FREQuency:STARt <frequency>
EMI Receiver Mode Reference 87

Table of Contents

Other manuals for Keysight EXA N9010A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight EXA N9010A and is the answer not in the manual?

Keysight EXA N9010A Specifications

General IconGeneral
BrandKeysight
ModelEXA N9010A
CategoryMeasuring Instruments
LanguageEnglish