183
➢ Previous Scanned Data – This option enables the user to compare the scanned
barcode with the previously scanned barcode and treat it as non-compliant data
if the user scanned the same barcode twice.
➢ All Stored Data – This option enables the user to compare the scanned barcode
with stored barcode data and treat it as non-compliant data if the same barcode
already scanned and stored.
⚫ Do not Save Non-Compliant Data
This field tells the KDC how to manage non-compliant data based on the defined data
filtering fields. If this field is enabled, non-compliant data is NOT stored in the KDC. If
this option is not enabled, non-compliant data is stored.
Generate step 2
To include another step in the data collection process, click the box, Generate step 2. This
step has the same options as Step 1. In this step, the user have the option of repeating step 2
by clicking the box, Repeat Step.
This field is disabled when the application has three steps.
Generate step 3
To include a third step, click the box, Generate step 3. This step has the same options as step 1
and 2. In this step, the user has the option to repeat steps 2 or 3.
Application Download and Execution
Before running your application, it must be downloaded to KDC.
1. Click the “Download” icon from Application Generation Window.
2. Change KDC from Normal mode to Application mode.
A. Press two side buttons simultaneously to enter menu mode.
B. Select KDC mode and enter scan button.
C. Change to Application mode.
D. Save and exit from menu mode.
3. KDC will run in normal mode if you do not change to Application mode after
downloading the application.
4. If you want to delete the downloaded application in your KDC, select App. Data
in Reset Memory after you go to System Config in KDC Menu.