TABLE IV: DID PANEL FAULT CODES (Cont.)
EVENT
DESCRIPTION
EVENT
RESTRICTION
DETECTION
INFORMATION
EVENT
NUMBER
Limp
Possible
Lockout
Limit
:05 high dc buss when running None
High dc bus voltage detected during
operation.
:06 high dc buss after pc powerup None
High dc bus voltage detected after
phase controller powerup.
:07 blower control fault None
Fault detected after phase controller
powerup.
:08 high dc buss when running None
High dc bus voltage detected during
operation.
:09
overcurrent after pc powerup, current
overload
None
Overcurrent condition detected after
phase controller power up.
:10 current overload None Sustained current overload exists.
:11 low dc buss overcurrent None Overcurrent due to low dc bus voltage.
:12 low dc buss current overload None
Sustained current overload due to low
dc bus voltage.
:13 gate drive trip None
IGBT protection circuit detected
overload.
:14 no input voltage None Zero input voltage detected.
637 AUX DC LINK HOT None
Auxiliary inverter DC link energized
while traction inverter DC link
de-energized.
N/A
691 PSC COMM. FAULT None
A PSC communication error has
occurred.
N/A 10
:01 missing message None
A PSC communication error has
occurred.
:02 bad tick None
A PSC communication error has
occurred.
:03 bad CRC None
A PSC communication error has
occurred.
:04 FIFO overflow None
A PSC communication error has
occurred.
:05 bad start bit None
A PSC communication error has
occurred.
:06 bad stop bit None
A PSC communication error has
occurred.
:07 message error None
A PSC communication error has
occurred.
696 UNEXPECTED TCI CPU RESET None TCI CPU reset without request.
698 DATA STORE None
A data snapshot has been manually
initiated.
699 SOFTWARE ERROR None Internal software fault.