a. Press top of switch to
the “On” (center posi-
tion), then press firmly
to the “Momentary” (up-
per position) and hold
briefly to activate the 5
Minute Idle Timer
(switch is spring-loaded
to return to “On” posi-
tion when released).
At the same time,
while
holding the the “momentary” switch position,
turn the keyswitch counterclockwise to the
OFF position.
When the engine stops after the 5 minute idle
period, the hydraulic bleeddown timer will be
activated and turn off the 24 VDC electrical
circuits controlled by the keyswitch.
The en-
gine will not shutdown if the keyswitch is
not turned OFF using this procedure.
b. When the Engine Shut-
down Timer has been
activated, the Timer De-
lay indicator light in the
overhead display panel
will illuminate to indicate
that the shutdown timing
sequence has been
started. The engine will continue to run at Idle
RPM for approximately 5 minutes to allow for
proper engine cool-down before stopping.
NOTE: To cancel the 5 Minute Idle Timer sequence,
press Timer Delay Shutdown switch to the “Off” (lower)
position.
•
••
•
If keyswitch is in “Off” position, engine will stop.
•
••
•
If keyswitch is in “On” position, engine will
continue to run.
A03017 General Safety and Operating Instructions A3-31