(E) 7-7
7. Operation Method
LH71A / LH72
Multiple datum point (datum point No. 1 ~)
<Setting a multiple datum point>
Display
1 Press the key. ( lamp lights up)
2 Using the numeric key, enter 1 and then press
the key. (The ABS lamp flashes.)
3 Press the key corresponding to the axis to be set.
4 Use the numeric key to enter the value.
5 Use the key to finalize the setting.
The current value becomes the set multiple datum point.
When the value of the multiple datum point is set, the
difference from the machining datum point is stored as
the offset value.
6 <Setting the next multiple datum point (max 150 points)>
Press the key.
Perform step 3 and after.
<Completing setting work>
Press the key.
The system exits the datum point mode. (The ABS lamp
flashes, and the lamp goes out.)
<Editing a multiple datum point>
You can edit a stored offset value.
Display
1 Press the key. ( lamp lights up)
2 Using the numeric key, enter the No. (example: 1)
that you want to edit and then press the key.
3 Press the key.
(Current value display)
(Current value display)
(Current value display)
(The last edited No.
followed by the current
value is displayed.)
(The value of the offset
from the machining datum
point is displayed.)
(The value of the offset
from the machining datum
point is displayed.)
(Example: 100.000)