Manitowoc Published 08-12-19, Control # 224-13 3-25
MLC650 OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
24 Cigarette Lighter
• Push IN to TURN ON lighter.
• The lighter will pop out when the coil is hot.
This receptacle can be used to power other 12VDC devices.
Maximum current draw is 10A.
25A Horn Switch (on console)
• Press and hold the TOP of the rocker to TURN ON the horn.
• RELEASE the rocker to TURN OFF the horn.
Before swinging or traveling, sound the horn to alert nearby
personnel.
25B Horn Switch (on floor)
• PRESS and hold with your foot to TURN ON the horn.
• RELEASE to TURN OFF the horn.
Before swinging or traveling, sound the horn to alert nearby personnel.
26 Jog Dial
Used in conjunction with the Crane Control System (CCS). See the MLC650
Main Display Operation Manual and the RCL/RCI Operation Manual for more
information.
27 Drum Identifier
Displays the drum number controlled by the
corresponding control handle. See Drum and Control
Handle Identification on page 3-56.
28 Drum Control Handles
See Load Drum Operation on page 3-71
.
The position of the drum handles can vary depending on crane configuration.
See Drum and Control Handle Identification on page 3-56
.
• Pull the control handle BACK to RAISE the load. The drum brake releases
and speed increases in relation to control handle movement.
• Release the control handle to CENTER to STOP the load. Speed decreases
to off and the drum brake applies to stop and hold the drum in position.
• Push the control handle FORWARD to LOWER the load. The drum brake
releases and speed increases in relation to control handle movement.
NOTE Some items cannot be operated at the same time. See Operation of
Diverting Circuits on page 3-27 for a list of diverting conditions.
Table 3-6. Right Console