Manitowoc Published 08-12-19, Control # 224-13_v2 4-45
MLC650 OPERATOR MANUAL SET-UP AND INSTALLATION
Connect the Live Mast Hydraulic and
Electrical
See Figure 4-36 for the following procedure:
1. Connect the two, drum 4 pawl hydraulic connections (1).
2. Remove the four, drum 4 hydraulic connections (2a)
from the stored position.
3. Connect the four, drum 4 hydraulic connections (2b) to
the working position.
4. Connect the drum 4 electrical connector (3) to the
second plug connector from the top of the receptacle
bracket.
5. Remove the two hydraulic connections (4a) from the
stored position.
6. Connect the two hydraulic connections (4b) on the left
side for the live mast assist cylinders.
7. Connect the live mast electrical plug (5).
8. Connect the live mast grounding wire (6) to the rotating
bed.