EasyManua.ls Logo

Metronix smartServo BL 4104-C - Tabs: Time Base

Default Icon
298 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Additional settings
7.2.2.2 Tabs: Time base
Figure 73: "Oscilloscope" window-"Time base" Tab
The upper Time slide can be used to define the time resolution. A value of 10 ms/div, for
example, means that the width of one square of the oscilloscope display corresponds to
10 ms.
The Delay slide can be used to determine the position of the trigger event on the
oscilloscope screen. 0 means that the trigger event will be displayed on the left-hand edge
of the oscilloscope screen. A negative delay value means that the events prior to the
occurrence of the trigger condition will also be recorded ("pretrigger"). In the case of a
negative value, the trigger mark will be shifted to the right into the oscilloscope screen.
The drop-down list Number of samples in the field Samples can be used to change the
number of recorded values per channel. Please note that the data transfer will take
considerably more time if the maximum number of samples is selected.
Product manual BL 4000-C Page 124 of 298

Table of Contents

Related product manuals