12 Technical data
Time Description Value
t
DRV
Delay of the internal sequence control of the
servo drive
10 ms max.
t
ENABHI
Time that DIN5 must be low after STOA/B has
been reactivated and the status of the STO
circuit has changed
> 20 ms
t
A
Switch-off delay of the holding brake See section 7.10 Brake
control and automatic
brake on page 182.
t
F
Switch-on delay of the holding brake See section 7.10 Brake
control and automatic
brake on page 182.
12.12 MicroSD card
Communication interface Value
File system FAT16, FAT32
Connector type microSD card
File names Only file and folder names that comply with the 8.3
standard are supported.