2 - F - 8
WRITE UNIT
(8) MIND CHG (CB IPB)
This signal selects the index signal.
[H]: External index signal
[L]: Internal index signal
(9) CORR (CB IPB)
White data collection trigger used when shading cor-
rection is taking place
(10)RESET (CB IPB)
Processing CPU reset signal (not used)
b. CB input signal
(1) IP REQ (IPB CB)
Processing board communications enable signal
(2) INDEX (IPB CB)
Write system index signal
(3) TXA 0, 1 (IPB CB)
Data that is transferred serially from the IPB to the CB
(4) MPR (IPB CB)
Image processing board power supply monitoring sig-
nal (connector check)
(5) O YOBI 1 (IPB CB)
Spare output port
c. IPB output signal
(1) M40 PWR A (IPB M40)
M40 A phase drive signal
(2) M40 PWR B (IPB M40)
M40 B phase drive signal
(3) M40 DRIVE A/A' (IPB M40)
M40 A phase drive pulse signal
(4) M40 DRIVE B/B' (IPB M40)
M40 B phase drive pulse signal
(5) LD1 APC CONT 1, 2 (IPB LDB1)
APC (laser light intensity automatic adjustment) of
LD1 takes place according to the combination of
these two signals.
(6) LD1 VIDEO (IPB LDB1)
LD1 laser image data
(7) LD1 IRCLK (IPB LDB1)
LD1 APC clock signal
(8) LD1 DACK (IPB LDB1)
LD1 MPC signal
(9) LD1 DI (IPB LDB1)
LD1 MPC signal
(10)LD2 LOAD (IPB LDB2)
LD2 MPC signal
(11)LD2 APC CONT 1, 2 (IPB LDB2)
APC (laser light intensity automatic adjustment) of
LD2 takes place according to the combination of
these two signals.
(12)LD VIDEO (IPB LDB2)
LD2 laser image data
(13)LD2 IRCLK (IPB LDB2)
LD2 APC clock signal
(14)LD2 DACK (IPB LDB2)
LD2 MPC signal
(15)LD2 DI (IPB LDB2)
LD2 MPC signal
(16)LD1 LOAD (IPB LDB1)
LD2 MPC signal
(17)HLVL (IPB INDEXSB)
5 VDC for monitoring power supply
d. IPB input signals
(1) LD1 ALM (LDB1 IPB)
Signal which indicates an abnormality in the laser drive
current
[H]: Normal
[L]: Abnormal
(2) LD2 ALM (LDB2 IPB)
Signal which indicates an abnormality in the laser drive
current
[H]: Normal
[L]: Abnormal
(3) M INDEX 1, 2 (INDEXSB IPB)
Index signal for detection of main scanning skew
(4) S INDEX 1, 2 (INDEXSB IPB)
Index signal for detection of sub scanning skew
(5) IPR (INDEXSB IPB)
INDEXSB power supply monitoring signal (connector
check)
[H]: Normal
[L]: Abnormal
(6) LD1 LPR (LDB1 IPB)
LD1 power supply monitoring signal (connector check)
[H]: Normal
[L]: Abnormal
(7) LD2 LPR (LDB2 IPB)
LD2 power supply monitoring signal (connector check)
[H]: Normal
[L]: Abnormal