Page #222 background imageLoading...
Page #222 background image
B
SimulCrypt • ECMG Statistics
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
204
573408-001-a
EMMG Channel Details window definitions
Item Definition/Range
Stream Index
Identifies the window line item.
Stream ID
Shows the identifier of the EMM stream.
Stream EMMs
Counter for the number of EMM provision messages received within the
corresponding EMM stream.
Stream Errors
Counter for the errors detected for the corresponding EMM stream.
Stream Fault
Displays EMM Stream status.
Values are:
• ok
• indeterminate
• warning
• minor
• major
• critical
ECMG Statistics
This window provides information on the status of ECM streams currently active in the
SimulCrypt network. For access, select SimulCrypt > ECMG Statistics:
Figure 10-12 — ECMG Statistics
Note: All values in this window are read-only.