Chapter 4 I/O SETTINGS
Chapter 4
Settings for I/O
4-27
ZW
User’s Manual
GATE signal setting
Sets the output time for the synchronization signal (GATE) for taking in signals
externally.
As an example, here is an explanation of the procedure for setting the output time to
"100 ms".
Operating procedure
Setting [Display] Description
GATE period [GATE] The GATE signal is output for the set time.
Steps
Key operation Display Description
1 - 3 For moving to BINARY, see steps 1 to 3 in p.4-22
4 Press or keys to select either of "GATE" and
press key.
5 Set "100" as the output time.
The current setting value is displayed on the sub-
display.
Press key to enter the editing mode, and the
sub-display blinks.
To edit numerical values use / / / keys.
Enter "100" and press key.
6 Press key for two seconds to enter the RUN
mode.