Chapter 4 I/O SETTINGS
Chapter 4
Timing Charts
4-35
ZW
User’s Manual
(Caution)
When the setting for non-measurement is "Clamp", if the sampling value is an abnormal value or an
undetermined value *, sampling is not executed. If sampling has been started, it is stopped. The output
value is as follows.
- The clamp value is held.
- If the previous hold value is not the clamp value, the GATE signal is output.
To start and continue sampling even if a sampling value is an abnormal value or an undetermined value,
set "Keep" as the non-measurement setting.
* After the start of measurement, if measurement results are not obtained the number of times required to
take the average, the measurement result is not applied.