EasyManua.ls Logo

Omron ZW Series - Page 167

Omron ZW Series
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 I/O SETTINGS
Chapter 4
Timing Charts
4-39
ZW
User’s Manual
(Caution)
When the setting for non-measurement is "Clamp", if the sampling value is an abnormal value or an
undetermined value *, sampling is not executed. The output value is as follows.
- The clamp value is held.
- If the previous hold value is not the clamp value, the GATE signal is output.
- The BUSY signal is not turned ON.
* After the start of measurement, if measurement results are not obtained the number of times required to
take the average, the measurement result is not applied.

Table of Contents

Other manuals for Omron ZW Series

Related product manuals