4. For the servo amplifier and R
TEX statuses during commissioning, check the "Status" and
"Error" groups.
4-1 To erase errors that are displayed, click the [Clear] button or [All Clear ] button in the
"Error" group.
Pressing the [Clear] button will erase axis errors, drive errors, RTEX errors, and
FB errors [0].
Pressing the [All Clear] button will erase axis errors, drive errors, RTEX errors,
and FB errors [0] to [5].
If the display of FB errors is collapsed, the number of FB errors will be displayed as
"0" in the "Error Content" column.
5. From the menu bar, select Project>Online Config Mode.
If online config mode is canceled, commissioning will be terminated.
This completes commissioning for servo amplifiers.
8.10 Commissioning