11.5.8 SMC_CNC_REF and SMC_OUTQUEUE
Two compilation modes are available for CNC tables. They can be selected when a table is
created.
For details on how to set compilation mode, refer to "1
1.5.4 Registering a CNC Table".
SMC_OutQueue (Pre-registration mode)
Data structure is generated during compilation.
A CNC table that has been set up can be specified directly in PMC_Interpolator2D or
PMC_Interpolator3D.
Because calculations are performed during compilation, high-speed operation can be
achieved.
Operation cannot be changed using programs.
CNC tables cannot be joined or repeated.
SMC_CNC_REF
After being decoded with PMC_NCDecoder, a CNC table that has been set up must be
executed in PMC_Interpolator2D or PMC_Interpolator3D.
Operation can be changed using programs (refer to "11.5.16 Interpolation Operation
Programming: Changing Parameter Settings (Converting to Variables in CNC Table)").
11.5 Multi-axis Operation