● For ring counters, comparison data can be set in an area including the lower and upper limits
where count values are rolled over
.
■
Parameter settings for external output function
● The comparison match 0 flag and comparison match 1 flag can be output externally using
parameter settings.
● The Counter_Configuration parameter window is used to allocate the comparison match 0
flag and comparison match 1 flag to the external output function.
● For details on how to set up parameters, refer to "12.6.2 Setting Parameters with GM
Programmer".
12.6.8 External Output Function
■
Overview of external output function
The comparison match 0 flag and comparison match 1 flag can be output externally using
parameter settings.
Setup procedure
1.
From "Device view" in the navigator pane, double-click "Counter_Configuration".
2. Click the "Counter parameter" tab.
3. For each counter, select "External output function "and set up each parameter.
12.6 High-speed Counter Function
WUME-GM1RTXOP-01 12-47