This method is used when target multi-stage velocities are specified in a sequence of motions.
C-point control
C-point control refers to control passing through a "Continuance Point". In this manual, this
control is referred to as "C-point control" for the sake of convenience. This method is used to
execute consecutive E-point controls by one-time startup.
When one movement is completed, it stops and then next movement is started.
This also applies to movements when dwell time is set. (If dwell time is set to 0 ms, continuous
movements will occur without waiting time.)
For C-point control, the GM1 controller supports the use case patterns shown in the table
below.
C-point control for connection between paths
This refers to connection between movements within a single CNC table.
C-point control for connection between CNC tables
This refers to connection between movements across CNC tables.
Use case
Applicable function
block
Restriction Remarks
C-point control for
connection between
paths
PMC_Interpolator2D/3D
You cannot change
movements only in a
particular path connection
section. (Changes must
be unified within C-point
control.)
Specify relevant parameters for
PMC_Interpolator2D or
PMC_Interpolator3D. There is
no need to create a new use
case.
Refer to "1
1.5.14 Interpolation
Operation Programming:
Settings in POU for P-point
Control and C-point Control".
11.5 Multi-axis Operation